The inclusive office - requirements, standards and practical solutions.

Accessible design is more than a ramp at the entrance. Here is what actually needs planning into the layout, finishes and engineering for an office to work for every employee.

Most companies in Tashkent treat accessibility as a box to tick - fit a ramp, add a handrail, sign it off. In practice that leaves a wheelchair user able to enter the building but unable to reach their own desk, a meeting room or the washroom. Inclusive design works differently - it plans the space so one person's limitation never becomes their problem to solve alone.

The regulatory picture in Uzbekistan

The core document is KMK 2.08.02-09, Public Buildings and Facilities, which sets minimum requirements for corridor widths, control heights, washroom dimensions and evacuation routes for people with limited mobility. For office space leased in an existing building, the standard applies to whatever extent the building's structure technically allows, which is not a reason to ignore it altogether.

Alongside it, the 2021 edition of ISO 21542 on the accessibility and usability of the built environment is worth following for the finer detail - turning circle sizes, contrast marking, tactile guidance and acoustics at reception.

Key figures from the standards

  • Corridor width along desks - at least 1,200 mm for one-way movement, 1,800 mm for two-way.
  • Wheelchair turning circle - 1,500 mm across, clear of furniture and equipment.
  • Work surface height reachable from a wheelchair - 750-850 mm, or 650-1,200 mm on an adjustable desk.
  • Control height (switches, sockets, access readers) - 900-1,200 mm off the floor.
  • Door opening - at least 900 mm clear, with no threshold higher than 15 mm.
  • Accessible washroom - at least 1,800 by 2,200 mm, with grab rails on both sides of the toilet.

Entrances and reception

Reception is the first point where accessibility either works or does not. A desk with a single 1,100 mm height physically shuts a wheelchair user out of contact with staff. The standard fix is a combined desk with a lower section at 750-800 mm and at least 900 mm wide.

Three things matter at the entrance, automatic or easily opened doors (no more than 22 N of force), no level changes between the street and the lobby, and enough light for people with low vision (at least 200 lux at reception). Tactile floor guidance is not required in every office, but it matters in larger public spaces.

Desks and collaboration space

At least 5% of desks in an open-plan area should be usable from a wheelchair, with at least 700 mm of clearance under the desktop and 600 mm of depth, and unobstructed side access. Under hot-desking, that means enough height-adjustable desks to make this the norm rather than the exception.

Meeting rooms need the same treatment, a 900 mm door, a turning circle inside, and at least one seat accessible from the end or corner of the table. Standard 1,000 by 1,000 mm phone booths are not usable from a wheelchair, so if they are part of the fit-out, at least one private space in a different format is needed too.

In the kitchen and break-out areas, at least one section of the worktop and one cabinet should sit within reach. Coffee machines and microwaves are best kept no higher than 1,200 mm.

Acoustics and the sensory environment

Inclusion is not only physical access. Staff with hearing loss rely on visual signals, light indicators instead of audible alarms, captions on collaboration screens, a clear sightline to the speaker from anywhere in a meeting room. For staff who are autistic or have ADHD, acoustic damping in the open plan, quiet zones with no obligation to book, and lighting that adjusts without flicker all matter.

Lighting figures matter just as much - uniformity of at least 0.6 across task zones, glare kept under a UGR of 19, and local control where possible. Flooring plays a role too - a contrast strip 50-100 mm wide along evacuation routes helps people with low vision, and firm level surfaces work better than deep-pile carpet for wheelchair users.

Evacuation routes

An office above the ground floor needs a refuge area, a fire-rated space with a communicator on every level. This is both a KMK requirement and plain common sense, lifts are not used in an evacuation, and waiting for help on a stairwell landing is not a solution.

How to audit an existing office

A quick accessibility audit is something you can do yourself, take a wheelchair or ask a colleague to walk the route from entrance to reception to desk to meeting room to washroom to exit, and note every point where movement is impossible or needs outside help. Second, check the heights, readers, sockets, switches, coffee machines. Third, assess the lighting and the floor contrast at transitions between zones.

In a leased office, some of this sits with the landlord, the entrance, the lifts, washrooms in shared areas. Put it in the brief before the lease is signed, what the landlord commits to provide and what falls to the tenant's own fit-out.

An open-plan office with rows of desks under acoustic ceiling panels and staff working at laptops
Office design

We design for accessibility from the first sketch.

Accessibility is cheapest to build in at concept stage, not to fix afterwards. Our design team treats accessibility requirements as part of the brief, not as an afterthought.

Office design
Ready for a project?

Let's talk about your office.

Tell us about the brief. We reply within one business day and offer a free initial consultation.

Message us